Sutureless, rapid deployment valves and stented bioprosthesis in aortic valve replacement: recommendations of an International Expert Consensus Panel

Gersak, Borut, Fischlein, Theodor, Folliguet, Thierry, Meuris, Bart, Teoh, Kevin, Moten, Simon, Solinas, Marco, Miceli, Antonio, Oberwalder, Peter, Rambaldini, Manfredo, Bhatnagar, Gopal, Borger, Michael, Bouchard, Denis, Bouchot, Olivier, Clark, Stephen, Dapunt, Otto, Ferrarini, Matteo, Laufer, Guenther, Mignosa, Carmelo, Millner, Russell, Noirhomme, Philippe, Pfeiffer, Steffen, Ruyra-Baliarda, Xavier, Shrestha, Malakh, Suri, Rakesh, Troise, Giovanni, Diegeler, Anno, Laborde, Francois, Laskar, Marc, Najm, Hani and Glauber, Mattia (2016) Sutureless, rapid deployment valves and stented bioprosthesis in aortic valve replacement: recommendations of an International Expert Consensus Panel. European Journal of Cardio-Thoracic Surgery, 49 (3). pp. 709-718. ISSN 1010-7940

Full text not available from this repository. (Request a copy)
Official URL: https://doi.org/10.1093/ejcts/ezv369

Abstract

OBJECTIVES - After a panel process, recommendations on the use of sutureless and rapid deployment valves in aortic valve replacement were given with special respect as an alternative to stented valves.

METHODS - Thirty-one international experts in both sutureless, rapid deployment valves and stented bioprostheses constituted the panel. After a thorough literature review, evidence-based recommendations were rated in a three-step modified Delphi approach by the experts.

RESULTS - Literature research could identify 67 clinical trials, 4 guidelines and 10 systematic reviews for detailed text analysis to obtain a total of 28 recommendations. After rating by the experts, 12 recommendations were identified and degree of consensus for each was determined. Proctoring and education are necessary for the introduction of sutureless valves on an institutional basis as well as for the individual training of surgeons. Sutureless and rapid deployment should be considered as the valve prosthesis of first choice for isolated procedures in patients with comorbidities, old age, delicate aortic wall conditions such as calcified root, porcelain aorta or prior implantation of aortic homograft and stentless valves as well as for concomitant procedures and small aortic roots to reduce cross-clamp time. Intraoperative transoesophageal echocardiography is highly recommended, and in case of right anterior thoracotomy, preoperative computer tomography is strongly recommended. Suitable annular sizes are 19–27 mm. There is a contraindication for bicuspid valves only for Type 0 and for annular abscess or destruction due to infective endocarditis. Careful but complete decalcification of the aortic root is recommended to avoid paravalvular leakage; extensive decalcification should be avoided not to create annular defects. Proximal anastomoses of concomitant coronary artery bypass grafting should be placed during a single aortic cross-clamp period or alternatively with careful side clamping. Available evidence suggests that the use of sutureless and rapid deployment valve is associated with (can translate into) reduced early complications such as prolonged ventilation, blood transfusion, atrial fibrillation, pleural effusions and renal replacement therapy, respectively, and may result in reduced intensive care unit and hospital stay in comparison with traditional valves.

CONCLUSION - The international experts recommend various benefits of sutureless and rapid deployment technology, which may represent a helpful tool in aortic valve replacement for patients requiring a biological valve. However, further evidence will be needed to reaffirm the benefit of sutureless and rapid deployment valves.

Item Type: Article
Uncontrolled Keywords: Aortic valve replacement, Sutureless valve, Rapid deployment valve, Stented aortic valve prosthesis, Recommendations
Subjects: A300 Clinical Medicine
B100 Anatomy, Physiology and Pathology
Department: Faculties > Health and Life Sciences > Applied Sciences
Depositing User: Becky Skoyles
Date Deposited: 29 Nov 2017 09:41
Last Modified: 12 Oct 2019 12:03
URI: http://nrl.northumbria.ac.uk/id/eprint/32687

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year

View more statistics