Atkinson, David, Pannell, Graham, Cao, Wenping, Zahawi, Bashar, Abeyasekera, Tusitha and Jovanovic, Milutin (2012) A doubly-fed induction generator test facility for grid fault ride-through analysis. IEEE Instrumentation & Measurement Magazine, 15 (6). pp. 20-27. ISSN 1094-6969
Full text not available from this repository. (Request a copy)Abstract
This paper has described a laboratory-scale DFIG test facility commissioned to investigate the low voltage fault behavior of a DFIG wind turbine generator. In this DFIG test facility, a dc motor driven by a four-quadrant dc drive is used as a prime mover to replicate the torque input from a wind turbine's drive shaft. A mechanical model created in Simulink is executed by the dSpace controller. The IGBT power converter and dc-link capacitors are over-rated to withstand various grid faults. The fault emulator permits a flexible approach to the application of grid faults and also provides an opportunity to mimic the typical grid connection impedance of a wind turbine.
Item Type: | Article |
---|---|
Subjects: | H600 Electronic and Electrical Engineering |
Department: | Faculties > Engineering and Environment > Mathematics, Physics and Electrical Engineering |
Depositing User: | Ay Okpokam |
Date Deposited: | 27 Mar 2013 14:05 |
Last Modified: | 12 Oct 2019 19:07 |
URI: | http://nrl.northumbria.ac.uk/id/eprint/11724 |