Bassarab, Paul, Williams, David, Dean, John, Ludkin, Edwin and Perry, Justin (2011) Determination of quaternary ammonium compounds in seawater samples by solid-phase extraction and liquid chromatography–mass spectrometry. Journal of Chromatography A, 1218 (5). pp. 673-677. ISSN 0021-9673
Full text not available from this repository. (Request a copy)Abstract
A method for the simultaneous determination of two biocidal quaternary ammonium compounds; didecyldimethylammonium chloride (didecyldimethyl quat) and dodecylbenzyldimethylammonium chloride (benzyl quat), in seawater by solid phase extraction (SPE) followed by liquid chromatography–mass spectrometry (LC–MS) was developed. The optimised procedure utilised off-line extraction of the analytes from seawater using polymeric (Strata-X) SPE cartridges. Recoveries ranged from 80 to 105%, with detection limits at the low parts-per-trillion (ng/l) level for both analytes. To demonstrate sensitivity, environmental concentrations were measured at three different locations along the North East coast of England with measured values in the range 120–270 ng/l.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Quaternary ammonium salts, Seawater-Analysis |
Subjects: | F100 Chemistry |
Department: | Faculties > Health and Life Sciences > Applied Sciences |
Depositing User: | EPrint Services |
Date Deposited: | 24 Feb 2011 10:08 |
Last Modified: | 12 Oct 2019 18:26 |
URI: | http://nrl.northumbria.ac.uk/id/eprint/1416 |