Liu, Chengyu, Zhang, Chengqiu, Zhang, Li, Zhao, Lina, Liu, Changchun and Wang, Hongjun (2015) Measuring synchronization in coupled simulation and coupled cardiovascular time series: A comparison of different cross entropy measures. Biomedical Signal Processing and Control, 21. pp. 49-57. ISSN 1746-8094
Full text not available from this repository. (Request a copy)Abstract
Synchronization provides an insight into underlying the interaction mechanisms among the bivariate time series and has recently become an increasing focus of interest. In this study, we proposed a new cross entropy measure, named cross fuzzy measure entropy (C-FuzzyMEn), to detect the synchronization of the bivariate time series. The performances of C-FuzzyMEn, as well as two existing cross entropy measures, i.e., cross sample entropy (C-SampEn) and cross fuzzy entropy (C-FuzzyEn), were first tested and compared using three coupled simulation models (i.e., coupled Gaussian noise, coupled MIX(p) and coupled Henon model) by changing the time series length, the threshold value for entropy and the coupling degree. The results from the simulation models showed that compared with C-SampEn, C-FuzzyEn and C-FuzzyMEn had better statistical stability and compared with C-FuzzyEn, C-FuzzyMEn had better discrimination ability. These three measures were then applied to a cardiovascular coupling problem, synchronization analysis for RR and pulse transit time (PTT) series in both the normal subjects and heart failure patients. The results showed that the heart failure group had lower cross entropy values than the normal group for all three cross entropy measures, indicating that the synchronization between RR and PTT time series increases in the heart failure group. Further analysis showed that there was no significant difference between the normal and heart failure groups for C-SampEn (normal 2.13 ± 0.37 vs. heart failure 2.07 ± 0.16, P = 0.36). However, C-FuzzyEn had significant difference between two groups (normal 1.42 ± 0.25 vs. heart failure 1.31 ± 0.12, P < 0.05). The statistical difference was larger for two groups when performing C-FuzzyMEn analysis (normal 2.40 ± 0.26 vs. heart failure 2.15 ± 0.13, P < 0.01).
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Cross entropy measure; Cardiovascular time series; Synchronization; Fuzzy measure entropy; RR interval; Pulse transit time |
Subjects: | B100 Anatomy, Physiology and Pathology G400 Computer Science |
Department: | Faculties > Engineering and Environment > Computer and Information Sciences |
Depositing User: | Becky Skoyles |
Date Deposited: | 06 Jul 2015 10:46 |
Last Modified: | 10 Oct 2019 16:18 |
URI: | http://nrl.northumbria.ac.uk/id/eprint/23252 |
Downloads
Downloads per month over past year