Moore, Sarah, Hickey, Aodhan, Lord, Sue, Del Din, Silvia, Godfrey, Alan and Rochester, Lynn (2017) Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study. Journal of NeuroEngineering and Rehabilitation, 14 (1). p. 130. ISSN 1743-0003
|
Text
s12984-017-0341-z.pdf - Published Version Available under License Creative Commons Attribution 4.0. Download (518kB) | Preview |
Abstract
Background
Application of objective measurement of stroke gait with accelerometer-based wearable technology and associated algorithms is increasing, despite reports questioning the accuracy of this technique in quantifying specific stroke-related gait impairments. The aim of this study is to determine the feasibility, validity and reliability of a low-cost open-source system incorporating algorithms and a single tri-axial accelerometer-based wearable to quantify gait characteristics in the laboratory and community post-stroke.
Methods
Twenty-five participants with stroke wore the wearable (AX3, Axivity) on the lower back during a laboratory 2 minute continuous walk (preferred pace) on two occasions a week apart and continuously in the community for two consecutive 7 day periods. Video, instrumented walkway (GaitRite) and an OPAL accelerometer-based wearable were used as laboratory references.
Results
Feasibility of the proposed system was good. The system was valid for measuring step count (ICC 0.899). Inherent differences in gait quantification between algorithm and GaitRite resulted in difficulties comparing agreement between the different systems. Agreement was moderate-excellent (ICC 0.503–0.936) for mean and variability gait characteristics vs. OPAL. Agreement was moderate-poor between the system and OPAL for asymmetry characteristics. Moderate-excellent reliability (ICC 0.534–0.857) was demonstrated for 11/14 laboratory measured gait characteristics. Community test-retest reliability was good-excellent (ICC 0.867–0.983) for all except one (ICC 0.699) of the 19 gait characteristics.
Conclusion
The proposed system is a low-cost, reliable tool for quantifying gait post-stroke with multiple potential applications. Further refinement to optimise gait quantification algorithms for certain gait characteristics including gait asymmetry is required.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | stroke, gait, physical activity, reliability, validity, accelerometer, accelerometre |
Subjects: | B800 Medical Technology |
Department: | Faculties > Engineering and Environment > Computer and Information Sciences Faculties > Health and Life Sciences > Sport, Exercise and Rehabilitation |
Depositing User: | Ay Okpokam |
Date Deposited: | 02 Jan 2018 12:43 |
Last Modified: | 31 Jul 2021 13:30 |
URI: | http://nrl.northumbria.ac.uk/id/eprint/32932 |
Downloads
Downloads per month over past year