Daunton, Rachael, Gallant, Andrew and Wood, David (2012) Manipulation of 10 – 40 μm Diameter Cells Using a Thermally Actuated Microgripper. MRS Proceedings, 1463. mrss12-1463. ISSN 1946-4274
Full text not available from this repository. (Request a copy)
Official URL: https://doi.org/10.1557/opl.2012.1072
Abstract
This work presents the successful fabrication of a thermally actuated U-shaped microgripper that has been specially designed to enable low voltage operation for bidirectional in plane deflection. The microgripper tips are carefully designed to match the biological species being manipulated, which has been demonstrated by the successful manipulation of 10 – 40 μm diameter particles used to simulate biological cells.