Highly sensitive twist sensor based on partially silver coated hollow core fiber structure

Liu, Dejun, Kumar, Rahul, Wei, Fangfang, Han, Wei, Mallik, Arun, Yuan, Jinhui, Yu, Chongxiu, Kang, Zhe, Li, Feng, Liu, Zhengyong, Tam, Hwa-Yaw, Farrell, Gerald, Semenova, Yuliya and Wu, Qiang (2018) Highly sensitive twist sensor based on partially silver coated hollow core fiber structure. Journal of Lightwave Technology, 36 (17). pp. 3672-3677. ISSN 0733-8724

[img]
Preview
Text
Twist sensor-JLT-22075-2018-Revised Final.pdf - Accepted Version

Download (998kB) | Preview
Official URL: http://doi.org/10.1109/JLT.2018.2842111

Abstract

Interferometer based on multiple beam interferences inside a hollow core fiber (HCF) structure (also known as an anti-resonant reflecting optical waveguide) has been attracting interest of many researchers due to its periodic transmission spectrum containing high quality factor spectral dips. Functionalized HCF structures have been demonstrated for a wide range of applications in humidity, magnetic field and bio-sensing. Here, we report a new application of the HCF based structure with a partial silver coating layer for sensing of twist. It is configured by fusion splicing a section of 4.5-mm long HCF between two standard single mode fibers (SMFs), followed by a sputter-coating of a very thin layer of silver on one side of the HCF surface. It is found that the spectral response of the partially silver coated HCF structure is very sensitive to the changes of input light polarization. An increase in sensitivity of the fiber structure to twist after deposition of the silver coating when twist is applied to both the SMF and HCF sections is demonstrated by comparison with an uncoated HCF fiber structure. Experimental results show that twisting of the HCF section results in much greater changes in a selected dip’s strength compared to that in the case of twisting the SMF section of the structure. The proposed HCF fiber sensors with 4.5 nm and 6.7 nm-thick silver layers show the highest sensitivities of 0.647 dB/°and 0.717 dB/° in the twist angles range of up to 10°. To the best of our knowledge, this is the highest twist sensitivity reported for intensity modulation based fiber sensors. Moreover, the proposed sensor offers excellent measurement repeatability.

Item Type: Article
Subjects: F300 Physics
Department: Faculties > Engineering and Environment > Mathematics, Physics and Electrical Engineering
Depositing User: Becky Skoyles
Date Deposited: 29 May 2018 11:29
Last Modified: 01 Aug 2021 09:36
URI: http://nrl.northumbria.ac.uk/id/eprint/34380

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year

View more statistics