The Siconolfi step test: a valid and reliable assessment of cardiopulmonary fitness in older men with prostate cancer

Lemanska, Agnieszka, Poole, Karen, Aning, Jonathan, Griffin, Bruce, Manders, Ralph, Saxton, John, Wainwright, Joe and Faithfull, Sara (2019) The Siconolfi step test: a valid and reliable assessment of cardiopulmonary fitness in older men with prostate cancer. European Review of Aging and Physical Activity, 16. p. 1. ISSN 1813-7253

[img]
Preview
Text
Lemanska2019_Article_TheSiconolfiStepTestAValidAndR.pdf - Published Version
Available under License Creative Commons Attribution 4.0.

Download (1MB) | Preview
Official URL: http://dx.doi.org/10.1186/s11556-018-0207-9

Abstract

Background
Assessing fitness and promoting regular physical activity can improve health outcomes and early recovery in prostate cancer. This is however, underutilised in clinical practice. The cardiopulmonary exercise test (CPET) is increasingly being used pre-treatment to measure aerobic capacity and peak oxygen consumption (VO2peak - a gold standard in cardiopulmonary fitness assessment). However, CPET requires expensive equipment and may not always be appropriate. The Siconolfi step test (SST) is simpler and cheaper, and could provide an alternative.

The aim of this study was to evaluate the validity and reliability of SST for predicting cardiopulmonary fitness in men with prostate cancer. Men were recruited to this two-centre study (Surrey and Newcastle, United Kingdom) after treatment for locally advanced prostate cancer. They had one or more of three risk factors: elevated blood pressure, overweight (BMI > 25), or androgen deprivation therapy (ADT). Cardiopulmonary fitness was measured using SST and cycle ergometry CPET, at two visits three months apart. The validity of SST was assessed by comparing it to CPET. The VO2peak predicted from SST was compared to the VO2peak directly measured with CPET. The reliability of SST was assessed by comparing repeated measures. Bland-Altman analysis was used to derive limits of agreement in validity and reliability analysis.

Results
Sixty-six men provided data for both SST and CPET. These data were used for validity analysis. 56 men provided SST data on both visits. These data were used for reliability analysis. SST provided valid prediction of the cardiopulmonary fitness in men > 60 years old. The average difference between CPET and SST was 0.64 ml/kg/min with non-significant positive bias towards CPET (P = 0.217). Bland-Altman 95% limits of agreement of SST with CPET were ± 7.62 ml/kg/min. SST was reliable across the whole age range. Predicted VO2peak was on average 0.53 ml/kg/min higher at Visit 2 than at Visit 1 (P = 0.181). Bland-Altman 95% limits of agreement between repeated SST measures were ± 5.84 ml/kg/min.

Conclusions
SST provides a valid and reliable alternative to CPET for the assessment of cardiopulmonary fitness in older men with prostate cancer. Caution is advised when assessing men 60 years old or younger because the VO2peak predicted with SST was significantly lower than that measured with CPET.

Item Type: Article
Subjects: B100 Anatomy, Physiology and Pathology
Department: Faculties > Health and Life Sciences > Sport, Exercise and Rehabilitation
Depositing User: Becky Skoyles
Date Deposited: 24 Jan 2019 11:17
Last Modified: 01 Aug 2021 07:35
URI: http://nrl.northumbria.ac.uk/id/eprint/37723

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year

View more statistics