Seves, Bregje L., Hoekstra, Femke, Schoenmakers, Jorrit W.A., Brandenbarg, Pim, Hoekstra, Trynke, Hettinga, Florentina, Dekker, Rienk, van der Woude, Lucas H.V. and van der Schans, Cees P. (2021) Test-retest reliability and concurrent validity of the Adapted Short QUestionnaire to ASsess Health-enhancing physical activity (Adapted-SQUASH) in adults with disabilities. Journal of Sports Sciences, 39 (8). pp. 875-886. ISSN 0264-0414
|
Text (Final published version)
02640414.2020.pdf - Published Version Available under License Creative Commons Attribution 4.0. Download (1MB) | Preview |
|
|
Text (Advance online version)
Test retest reliability and concurrent validity of the Adapted Short QUestionnaire to ASsess Health enhancing physical activity Adapted SQUASH in.pdf - Published Version Available under License Creative Commons Attribution 4.0. Download (947kB) | Preview |
Abstract
The current study determined the test-retest reliability and concurrent validity of the Adapted Short QUestionnaire to ASsess Health-enhancing physical activity (Adapted-SQUASH) in adults with disabilities. Before filling in the Adapted-SQUASH twice with a recall period of 2 weeks, participants wore the Actiheart activity monitor up to 1 week. For the test-retest reliability (N = 68), Intraclass correlation coefficients (ICCs) were 0.67 (p <0.001) for the total activity score (min x intensity/week) and 0.76 (p <0.001) for the total minutes of activity (min/week). For the concurrent validity (N = 58), the Spearman correlation coefficient was 0.40 (p = 0.002) between the total activity score of the first administration of the Adapted-SQUASH and activity energy expenditure from the Actiheart (kcals kg min ). The ICC was 0.22 (p = 0.027) between the total minutes of activity assessed with the first administration of the Adapted-SQUASH and Actiheart. The Adapted-SQUASH is an acceptable measure to assess self-reported physical activity in large populations of adults with disabilities but is not applicable at the individual level due to wide limits of agreement. Self-reported physical activity assessed with the Adapted-SQUASH does not accurately represent physical activity assessed with the Actiheart in adults with disabilities, as indicated with a systematic bias between both instruments in the Bland-Altman analysis.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Physical activity assessment, accelerometer, chronic disease, health promotion, rehabilitation |
Subjects: | B100 Anatomy, Physiology and Pathology C600 Sports Science |
Department: | Faculties > Health and Life Sciences > Sport, Exercise and Rehabilitation |
Depositing User: | Rachel Branson |
Date Deposited: | 05 Jan 2021 15:52 |
Last Modified: | 31 Jul 2021 16:02 |
URI: | http://nrl.northumbria.ac.uk/id/eprint/45115 |
Downloads
Downloads per month over past year