Abstract

In the present study, heat transfer and thermal efficiency of double-pipe heat exchangers with novel Double-Perforated Inclined Elliptic (DPIE) turbulators were experimentally investigated. The range of Reynolds number was between 5000 and 18,000 under turbulent flow regime. The inclination angle of the elliptic inserts , and the perforation diameters (d) varied from 15° to 25°, and 0.5 mm < d < 1.5 mm, respectively. The perforated vortex generators can significantly increase the flow perturbations and disrupt the thermal boundary layer to enhance the heat transfer without noticeable impact on the friction loss. The experiments revealed that the average Nusselt number was increased by 217.4% by using DPIE turbulators compared to the tube without vortex generators. The recirculations through the perforations of the elliptic turbulators, increase the fluid mixing between the walls and the core area. The maximum thermal efficiency parameter of 1.849 was obtained for DPIE vortex generators with d/b = 0.25 and . The Friction factor increment of 14.0% was observed for the double perforated elliptic turbulators with d/b = 0.25 compared to the typical elliptic inserts without perforations. It was found that the heat transfer is increased around 39.4% by using DPIE inserts with d/b = 0.25 compared to the typical louvered strips without perforations. The main benefits of the proposed novel turbulators are their much higher thermal efficiency compared to the previous turbulators at wide range of Reynolds numbers, and their simple installation together with low manufacturing costs.

Item Type: Article
Uncontrolled Keywords: Thermal performance enhancement, Double-pipe heat exchanger, Perforated elliptic turbulators, Nusselt number, Friction loss
Subjects: H800 Chemical, Process and Energy Engineering
Department: Faculties > Engineering and Environment > Mechanical and Construction Engineering
Depositing User: John Coen
Date Deposited: 26 May 2021 07:34
Last Modified: 25 May 2022 03:31
URI: http://nrl.northumbria.ac.uk/id/eprint/46280

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year

View more statistics