Singlemode-Multimode-Singlemode Optical Fiber Sensor for Accurate Blood Pressure Monitoring

Pang, Yi-Neng, Liu, Bin, Liu, Juan, Wan, Shengpeng, Wu, Tao, Yuan, Jinhui, Xin, Xiangjun, He, Xing Dao and Wu, Qiang (2022) Singlemode-Multimode-Singlemode Optical Fiber Sensor for Accurate Blood Pressure Monitoring. Journal of Lightwave Technology, 40 (13). pp. 4443-4450. ISSN 0733-8724

[img]
Preview
Text
Blood_pressure_revised_final.pdf - Accepted Version

Download (1MB) | Preview
Official URL: https://doi.org/10.1109/JLT.2022.3155194

Abstract

A dual-channel single-mode-multi-mode-single-mode (SMS) fiber optic sensor encapsulated by polydimethylsiloxane (PDMS) was proposed for the first time, for the simultaneous monitoring of the brachial and radial arteries for accurate blood pressure prediction. With the help of the machine learning algorithm Support Vector Regression (SVR), the SMS fiber sensor can continuously and accurately monitor the systolic and diastolic blood pressure. Commercial sphygmomanometers are used to calibrate the accuracy of blood pressure measurement. Compared with the single-channel system, this system can extract more pulse wave features for blood pressure prediction, such as radial artery transit time (RPTT), brachial artery transit time (BPTT), and the transit time difference between the radial artery and the brachial artery (DBRPTT). The results show that the performance of dual-channel blood pressure monitoring is more accurate than that of single-channel blood pressure monitoring in terms of the absolute value of the correlation coefficient (R) and the average value of the difference between SBP and DBP. In addition, both the single-channel and dual-channel blood pressure monitoring are in line with the Association for the Advancement of Medical Devices (AAMI), but the average deviation (DM, 0.06 mmHg) and standard deviation (SD, 1.54 mmHg) of dual-channel blood pressure monitoring are more accurate. The blood pressure monitoring system has the characteristics of low cost, high sensitivity, non-invasive and capability for remote real time monitoring, which can provide effective solution for intelligent health monitoring in the era of artificial intelligence in the future.

Item Type: Article
Additional Information: Funding information: This work was supported by the National Natural Science Foundation of China (NSFC) (62175097, 62065013, 11864025, 61865013); Natural Science Foundation of Jiangxi Province (20192ACB20031, 20192ACBL21051 and 20202ACBL202002), Key R&D Projects of the Ministry of Science and Technology of China (2018YFE0115700); Royal Society International Exchanges 2020 Cost Share (NSFC) (IEC\NSFC\201015).
Uncontrolled Keywords: Blood pressure monitoring, SMS fiber sensors, Optical fiber sensors, Healthcare monitoring, Human pulse wave
Subjects: B800 Medical Technology
F300 Physics
H600 Electronic and Electrical Engineering
Department: Faculties > Engineering and Environment > Mathematics, Physics and Electrical Engineering